Product Details:
Payment & Shipping Terms:
|
| Product Name: | Oil Resistant Marine PVC Power Cable PVC Insulated Power Cable | Application: | Marine Deck And Engine Room Power Wiring |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper, IEC 60228 | Insulation: | Oil Resistant PVC, 90 Deg C Rated |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 4 X 16 Mm2 |
| Oil Resistance: | IEC 60811-404, 24 H At 100 Deg C | Chemical Resistance: | Resistant To Mineral Oil, Diesel, Hydraulic Fluid And Brine |
| Sheath Compound: | Oil Resistant PVC Compound ORM-90 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | Oil resistant marine PVC power cable,90 deg C engine room cable,Class 2 copper 4x16mm2 |
||
Deck and engine room circuits on working vessels are constantly exposed to fuel spillage, lubricating oil mist and hydraulic leaks, and a standard PVC sheath will soften and swell within months. This cable is built around a nitrile-modified oil resistant PVC compound that keeps its mechanical strength after prolonged contact with mineral oils and diesel, so insulation resistance stays stable across the whole service life.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper, IEC 60228 |
| Cross Section | 4 x 16 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | Oil resistant PVC, 90 deg C rated |
| Sheath | Oil resistant PVC compound ORM-90, black |
| Core Identification | Brown, black, grey, blue with yellow-green earth |
| Max Conductor Temperature | 90 deg C continuous, 160 deg C short circuit |
| Oil Swelling Test | IEC 60811-404, 24 h at 100 deg C |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 985 kg/km |
Construction summary: Class 2 stranded bare copper, IEC 60228 with Oil resistant PVC, 90 deg C rated, rated 0.6/1 kV and sheathed in Oil Resistant PVC Compound ORM-90. The 4 x 16 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe construction targets shipboard power distribution where cables are routed through engine compartments, pump rooms and open deck trays. Because the sheath is compounded for oil contact rather than merely splash resistance, the cable can be clipped directly along machinery frames without secondary conduit protection, which reduces installation time during refit works.
How does the cable behave after long term diesel contact? Sheath samples are tested to IEC 60811-404 and retain more than 75 percent of tensile strength and elongation after 24 hours immersion at 100 deg C. Swelling stays below the acceptance limit, so the outer diameter remains stable inside cable trays.
Can this cable be used in engine rooms above 70 deg C ambient? Yes. The insulation and sheath compounds are rated for 90 deg C continuous conductor temperature, which gives headroom for the 45 to 60 deg C ambient normally found near running machinery, and 160 deg C is allowed for short circuit periods up to five seconds.
Is a separate earth conductor required? The four core layout carries one yellow-green earth core, so single-cable feeds to motors and distribution boards can be wired without pulling an additional protective conductor.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.