Product Details:
Payment & Shipping Terms:
|
| Product Name: | Chemical Resistant PVC Sheathed Cable PVC Sheathed Cable | Application: | Chemical Plant And Plating Line Wiring |
|---|---|---|---|
| Conductor: | Class 1 Solid And Class 2 Stranded Bare Copper | Insulation: | PVC Type PVC/C, 70 Deg C |
| Rated Voltage: | 450/750 V | Core Configuration: | 3 X 2.5 Mm2 |
| Oil Resistance: | IEC 60811-404, 168 H At 90 Deg C | Chemical Resistance: | Resistant To Mineral Oil, Diesel, Hydraulic Fluid And Brine |
| Sheath Compound: | Chemical Resistant PVC Sheath CR-70 | Standard: | IEC 60227, IEC 60332-1 |
| Highlight: | Chemical resistant PVC sheathed cable,450/750V three core plant cable,Acid alkali proof copper cable |
||
Plant rooms in chemical works, surface treatment lines and plating shops attack ordinary PVC cable from the outside rather than the inside. Fumes, splash from acid baths and alkaline washdown liquor gradually extract plasticiser from a standard sheath until it cracks. This cable uses a chemically stabilised PVC compound with reduced plasticiser migration, tested by long duration immersion in diluted acid and alkali solutions.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 1 solid and Class 2 stranded bare copper |
| Cross Section | 3 x 2.5 mm2 |
| Rated Voltage | 450/750 V |
| Insulation | PVC type PVC/C, 70 deg C |
| Sheath | Chemical resistant PVC compound CR-70 |
| Core Identification | Brown, blue, yellow-green |
| Acid and Alkali Test | IEC 60811-404, 168 h immersion |
| Minimum Bending Radius | 8 times outer diameter |
| Standard | IEC 60227, IEC 60332-1 |
| Approx Weight | 148 kg/km |
Construction summary: Class 1 solid and Class 2 stranded bare copper with PVC type PVC/C, 70 deg C, rated 450/750 V and sheathed in Chemical Resistant PVC Sheath CR-70. The 3 x 2.5 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe product is intended for fixed wiring inside process buildings where cable routes pass close to reaction vessels, dosing stations and rinse tanks. Because the sheath resists both acidic and alkaline attack, the same cable type can run through different process zones without the installer having to select separate compounds for each area, which simplifies procurement on brownfield upgrades.
Which chemicals does the sheath resist? The compound is qualified against diluted sulphuric and hydrochloric acid, sodium hydroxide solutions, sodium hypochlorite and common plating bath vapours at concentrations typical of ambient splash exposure. Concentrated solvent contact still requires a protective conduit.
Is the cable suitable for washdown areas? Yes. The sheath has low water absorption and a smooth closed surface, so high pressure rinse water runs off instead of being retained, and insulation resistance recovers fully after wet service.
Can it be installed in cable trays shared with instrumentation? The three core construction with a yellow-green earth core allows it to be used for small power and lighting circuits in the same tray, provided the 450/750 V rating matches the circuit voltage and separation rules for signal cables are respected.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.