Product Details:
Payment & Shipping Terms:
|
| Product Name: | Alkali Resistant PVC Power Cable PVC Insulated Power Cable | Application: | Concrete Duct And Cement Plant Power Distribution |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper, IEC 60228 | Insulation: | PVC Type PVC/C, 70 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 3 X 95 Mm2 |
| Oil Resistance: | IEC 60811-404, 168 H At 90 Deg C | Chemical Resistance: | Resistant To Mineral Oil, Diesel, Hydraulic Fluid And Brine |
| Sheath Compound: | Alkali Resistant PVC Sheath AR-70 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | Alkali resistant PVC power cable,3x95mm2 concrete duct cable,High pH resistant copper cable |
||
Fresh concrete and cement slurry are strongly alkaline, and cables cast into ducts or buried beside cement plant structures often fail through sheath embrittlement rather than electrical fault. The sheath on this cable is compounded with an acid acceptor system that tolerates sustained high pH contact, verified by 168 hour immersion in saturated lime water.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper, IEC 60228 |
| Cross Section | 3 x 95 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | PVC type PVC/C, 70 deg C |
| Sheath | Alkali resistant PVC compound AR-70, black |
| Alkali Immersion Test | IEC 60811-404, saturated lime water 168 h |
| Core Identification | Brown, black, grey |
| Current Capacity in Air | 245 A per phase |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 3260 kg/km |
Construction summary: Class 2 stranded bare copper, IEC 60228 with PVC type PVC/C, 70 deg C, rated 0.6/1 kV and sheathed in Alkali Resistant PVC Sheath AR-70. The 3 x 95 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe construction is applied to medium sized distribution feeders in cement works, precast yards and buildings where cables are cast into concrete or laid in trenches that collect alkaline runoff. Because the sheath stays flexible after exposure, the cable can still be re routed during later building modifications without cracking at the bends.
Why does standard PVC fail in concrete ducts? Ordinary PVC slowly absorbs alkaline moisture from fresh concrete, which releases hydrogen chloride and embrittles the sheath. This compound includes an acid acceptor that neutralises the reaction, and testing in saturated lime water for 168 hours confirms that elongation at break stays within limits.
What current can three 95 mm2 copper cores carry? In free air at 30 deg C ambient the construction carries approximately 245 A per phase, and in ground at 20 deg C the figure rises to about 275 A. Actual derating depends on grouping and soil thermal resistivity on site.
Is the cable suitable for direct burial without ducting? It can be direct buried in soil with normal pH, but where the backfill contains fresh concrete rubble or cement residue the sheath benefits from a sand surround or duct to keep the alkaline load within the tested range.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.