Product Details:
Payment & Shipping Terms:
|
| Product Name: | Marine Grade Oil Resistant PVC Cable PVC Insulated Cable | Application: | Marine Machinery Space Power And Control Wiring |
|---|---|---|---|
| Conductor: | Class 2 Stranded Tinned Option Bare Copper | Insulation: | PVC, 90 Deg C Rated |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 3 X 16 Mm2 |
| Oil Resistance: | IEC 60811-404, IRM 902 Oil 168 H At 90 Deg C | Chemical Resistance: | Resistant To Mineral Oil, Diesel, Hydraulic Fluid And Brine |
| Sheath Compound: | Oil Resistant Low Smoke PVC Compound M-90 | Standard: | IEC 60092-353, IEC 60332-3-22 |
| Highlight: | Marine grade oil resistant PVC cable,Low smoke marine 3x16mm2 cable,IEC 60092-353 shipboard cable |
||
Machinery spaces on modern vessels need cable that tolerates oil contact without turning a small electrical fault into a smoke filled compartment. This marine grade cable uses an oil resistant PVC sheath with a low smoke additive package, so it survives continuous exposure to lubricating oil while producing limited smoke and low acid gas in a fire.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded tinned option bare copper |
| Cross Section | 3 x 16 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | PVC, 90 deg C rated |
| Sheath | Oil resistant low smoke PVC compound M-90 |
| Smoke Density | IEC 61034, light transmittance above 60 percent |
| Oil Immersion | IEC 60811-404, IRM 902 oil 168 h at 90 deg C |
| Halogen Content | IEC 60754-1, below 18 percent |
| Standard | IEC 60092-353, IEC 60332-3-22 |
| Approx Weight | 760 kg/km |
Construction summary: Class 2 stranded tinned option bare copper with PVC, 90 deg C rated, rated 0.6/1 kV and sheathed in Oil Resistant Low Smoke PVC Compound M-90. The 3 x 16 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable is specified for machinery space and auxiliary system wiring on vessels and offshore units where classification society rules require bunched flame propagation compliance. Because the same sheath handles oil contact and smoke control, cable trays can be routed through oily zones without additional sleeving or separate cable types.
Does the low smoke additive reduce oil resistance? No. The additive package is carried in an oil resistant base compound, and the sheath still passes 168 hour immersion in IRM 902 reference oil at 90 deg C with elongation retained above 70 percent of the original value, so both properties are maintained together.
Which fire tests does the cable satisfy? The construction is tested to IEC 60332-1 for single cable flame propagation and IEC 60332-3-22 category A for bunched cables in trays, and smoke density is verified to IEC 61034 with light transmittance above 60 percent.
Is tinned copper available for salty atmosphere protection? Yes. The conductor can be supplied with tinned strands to slow surface oxidation in humid, salt laden machinery spaces, which also improves solderability for small control terminations.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.