Product Details:
Payment & Shipping Terms:
|
| Product Name: | LSZH PVC Insulated Power Cable PVC Insulated Power Cable | Application: | Metro Station And Data Centre Power Distribution |
|---|---|---|---|
| Conductor: | Class 2 Compacted Stranded Bare Copper | Insulation: | LSZH PVC Compound, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 4 X 25 Mm2 |
| Halogen Content: | IEC 60754-1 Below 0.5 Percent HCl | Smoke Density: | IEC 61034-2, Transmittance Above 70 Percent |
| Sheath Compound: | Low Smoke Zero Halogen PVC Compound LS-90 | Standard: | IEC 60502-1, IEC 60332-3-24 |
| Highlight: | LSZH PVC insulated power cable,Low smoke halogen free 4x25mm2,IEC 60332-3-24 bunched cable |
||
Enclosed public spaces such as metro stations and data halls cannot rely on cable that emits dense smoke and corrosive acid gas during a fire, because evacuation and equipment survival depend on visibility and clean air. This cable replaces the conventional PVC sheath with a low smoke zero halogen compound while keeping the mechanical and electrical behaviour engineers expect from PVC insulated power cable.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 compacted stranded bare copper |
| Cross Section | 4 x 25 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | LSZH PVC compound, 90 deg C |
| Sheath | Low smoke zero halogen PVC compound LS-90 |
| Halogen Acid Gas | IEC 60754-1 below 0.5 percent HCl |
| Smoke Density | IEC 61034-2, transmittance above 70 percent |
| Toxicity Index | Below 5 according to EN 50305 |
| Standard | IEC 60502-1, IEC 60332-3-24 |
| Approx Weight | 1480 kg/km |
Construction summary: Class 2 compacted stranded bare copper with LSZH PVC compound, 90 deg C, rated 0.6/1 kV and sheathed in Low Smoke Zero Halogen PVC Compound LS-90. The 4 x 25 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe construction is used for low voltage distribution inside underground stations, tunnels, server halls and other spaces where fire performance is part of the building approval. Because the compound delivers both low smoke and low acid gas, the same cable satisfies life safety and asset protection requirements without the cost penalties of a full XLPE LSZH system.
What is the difference between LSZH and ordinary PVC? Ordinary PVC contains chlorine and releases hydrogen chloride when burned. The LSZH compound here is formulated so that acid gas generation stays below 0.5 percent and smoke transmittance remains above 70 percent, which protects both evacuation routes and sensitive electronics.
Can the cable be installed in the same tray as power and signal cables? The low smoke sheath reduces cross contamination in a fire, but electrical separation rules still apply. Keep signal cables at least 300 mm away, or use a metallic divider, to control electromagnetic coupling.
Does the LSZH sheath perform well outdoors? The compound includes a UV stabiliser for short outdoor exposures and duct entries. For permanent direct sunlight runs above two metres, an additional UV resistant oversheath or conduit is recommended.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.