Product Details:
Payment & Shipping Terms:
|
| Product Name: | Zero Halogen PVC Electrical Cable PVC Electrical Cable | Application: | Industrial Plant Escape Route And Switch Room Power |
|---|---|---|---|
| Conductor: | Class 2 Compacted Stranded Bare Copper | Insulation: | Zero Halogen Compound, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 3 X 70 Mm2 |
| Halogen Content: | IEC 60754-1 Below 0.5 Percent | Smoke Density: | IEC 61034-2 Above 70 Percent Transmittance |
| Sheath Compound: | Zero Halogen Fire Retardant Compound ZH-90 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | Zero halogen PVC electrical cable,Fire retardant 3x70mm2 1kV cable,Low smoke plant feeder cable |
||
Switch rooms and escape routes inside industrial plants need cable that will not fill the space with corrosive gas while operators are still trying to isolate equipment. This three core cable is built on a zero halogen compound with a fire retardant additive system, delivering both low smoke and restricted flame spread at 70 mm2 conductor size.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 compacted stranded bare copper |
| Cross Section | 3 x 70 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | Zero halogen compound, 90 deg C |
| Sheath | Zero halogen fire retardant compound ZH-90 |
| Halogen Content | IEC 60754-1 below 0.5 percent |
| Flame Propagation | IEC 60332-3-24 category C |
| Smoke Density | IEC 61034-2 above 70 percent transmittance |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 2890 kg/km |
Construction summary: Class 2 compacted stranded bare copper with Zero halogen compound, 90 deg C, rated 0.6/1 kV and sheathed in Zero Halogen Fire Retardant Compound ZH-90. The 3 x 70 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable is used for sub main feeders between plant substations and distribution boards serving escape routes, control rooms and protected switch rooms. It is also specified where insurance requirements demand halogen free construction for high value electrical assets, because soot and acid deposits are the main cause of collateral equipment loss after a cable fire.
Why specify zero halogen at 70 mm2 rather than small sizes only? Large feeders carry the highest fault energy and are usually the origin of plant cable fires. Using zero halogen construction at sub main size removes the main acid gas source instead of only protecting final circuits.
Does the fire retardant additive affect current capacity? No. The additive is carried in the sheath and does not change conductor temperature limits, so 70 mm2 copper cores still carry about 200 A per phase in air at 30 deg C, subject to normal grouping factors.
Can the cable be jointed with standard kits? Standard compression lugs and heat shrink joints are suitable, but the joint kit should also be halogen free if the fire performance of the circuit has to be maintained through the joint position.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.