Product Details:
Payment & Shipping Terms:
|
| Product Name: | LSOH Panel Wire 4mm2 PVC Insulated Wire | Application: | Control Panel And Switchgear Internal Wiring |
|---|---|---|---|
| Conductor: | Class 5 Fine Stranded Bare Copper | Insulation: | LSOH Compound, 105 Deg C |
| Rated Voltage: | 450/750 V | Core Configuration: | 1 X 4 Mm2 |
| Halogen Content: | IEC 60754-1 Below 0.5 Percent | Smoke Density: | IEC 61034-2 Above 70 Percent Transmittance |
| Sheath Compound: | Low Smoke Zero Halogen Compound LSOH-105 | Standard: | IEC 60227-3, IEC 60332-1 |
| Highlight: | LSOH panel wire 4mm2,Halogen free 105 deg C wire,Class 5 fine stranded panel wire |
||
Control panels concentrate heat, tight bends and sensitive electronics in one enclosure, so a small internal wire fire can destroy an entire switchboard through soot and acid deposits. This single core wire uses a 105 deg C low smoke zero halogen insulation on a fine stranded conductor, giving panel builders both thermal headroom and clean fire behaviour.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 5 fine stranded bare copper |
| Cross Section | 1 x 4 mm2 |
| Rated Voltage | 450/750 V |
| Insulation | LSOH compound, 105 deg C |
| Colour Range | Black, blue, brown, red, grey, yellow-green |
| Halogen Content | IEC 60754-1 below 0.5 percent |
| Smoke Density | IEC 61034-2 above 70 percent transmittance |
| Flex Rating | Class 5 stranding, 4 times diameter bend |
| Standard | IEC 60227-3, IEC 60332-1 |
| Approx Weight | 52 kg/km |
Construction summary: Class 5 fine stranded bare copper with LSOH compound, 105 deg C, rated 450/750 V and sheathed in Low Smoke Zero Halogen Compound LSOH-105. The 1 x 4 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe wire is intended for internal panel wiring of breakers, contactors, relays and terminal blocks in switchgear and control cabinets. Because the insulation tolerates 105 deg C, panels can be built more compactly without derating for ambient rise, and the halogen free compound protects sensitive electronic modules from corrosion after a fault.
Why use a 105 deg C insulation inside a panel rated 70 deg C? Panel internal ambient often reaches 55 to 65 deg C, and local hot spots near breakers run higher. A 105 deg C insulation gives margin so the wire does not age prematurely at these hot spots.
Does fine stranding cause termination problems? Class 5 conductors require bootlace ferrules for screw terminals. With ferrules the termination is mechanically reliable and the fine stranding actually helps where wires must fold into tight ducts.
Is the wire suitable for retrofit work in existing panels? Yes. The insulation strips cleanly and accepts standard ferrules, so retrofit wiring can be completed without changing existing terminal hardware, while the halogen free compound improves the fire profile of older cabinets.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.