Product Details:
Payment & Shipping Terms:
|
| Product Name: | Smoke Free Halogen Free PVC Cable PVC Insulated Cable | Application: | Ship Accommodation And Public Space Power Wiring |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper | Insulation: | Halogen Free Compound, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 4 X 35 Mm2 |
| Halogen Content: | IEC 60754-1 Below 0.5 Percent | Smoke Density: | IEC 61034-2 Above 75 Percent Transmittance |
| Sheath Compound: | Smoke Free Halogen Free Compound SF-90 | Standard: | IEC 60092-353, IEC 60332-3-22 |
| Highlight: | Smoke free halogen free PVC cable,Ship accommodation 4x35mm2 cable,Low toxicity marine cable |
||
Accommodation spaces are where cable fire performance matters most to people rather than equipment, since corridors and stairways are the only escape route. This cable is built with halogen free insulation and a smoke free sheath that keeps light transmittance above 75 percent, so emergency lighting remains effective while passengers move to muster stations.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper |
| Cross Section | 4 x 35 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | Halogen free compound, 90 deg C |
| Sheath | Smoke free compound SF-90, black |
| Smoke Density | IEC 61034-2 above 75 percent transmittance |
| Halogen Content | IEC 60754-1 below 0.5 percent |
| Toxicity | EN 50305 index below 5 |
| Standard | IEC 60092-353, IEC 60332-3-22 |
| Approx Weight | 1780 kg/km |
Production follows a documented inspection plan with inline diameter, concentricity and spark testing before the cable reaches final packing.
Construction summary: Class 2 stranded bare copper with Halogen free compound, 90 deg C, rated 0.6/1 kV and sheathed in Smoke Free Halogen Free Compound SF-90. The 4 x 35 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable feeds cabin distribution boards, corridor lighting and public space services on passenger vessels and offshore accommodation units. Because toxicity is measured to EN 50305 as well as smoke density to IEC 61034, the construction supports the fire safety case required for passenger ship approval.
How is low toxicity demonstrated? The cable is assessed to EN 50305, which measures the toxicity index of combustion gases. A result below 5 indicates limited production of incapacitating gases, and this is reported alongside smoke density for passenger ship approval packages.
Does the sheath stay flexible at low temperatures? The compound passes a cold bend test at minus 15 deg C, which covers unheated deck storerooms and cargo areas during winter operation, while normal accommodation service remains well within its elastic range.
Can it be run in the same trunking as fire alarm cable? Physical separation is still required between power and fire alarm circuits. Use separate trunking compartments or a metallic divider, since smoke performance does not replace circuit integrity requirements.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.