Product Details:
Payment & Shipping Terms:
|
| Product Name: | UV Resistant Outdoor PVC Cable PVC Insulated Cable | Application: | Outdoor Aerial And Pole Mounted Power Distribution |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper | Insulation: | UV Stabilised PVC, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 4 X 35 Mm2 |
| UV Resistance: | ISO 4892-3, 2000 H Xenon Arc Exposure | Weather Resistance: | No Cracking After 96 H At 50 Pphm |
| Sheath Compound: | UV Stabilised PVC Compound UV-90 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | UV resistant outdoor PVC cable,Aerial 4x35mm2 1kV cable,Weatherproof stabilised copper cable |
||
Cable installed on poles, rooftops or open racks spends years under direct sun, and ultraviolet radiation is what ends its life, not electrical load. The sheath on this cable is loaded with carbon black and a hindered amine stabiliser package, tested for 2000 hours of xenon arc exposure, so surface cracking and chalking are delayed well beyond the normal service life of a distribution feeder.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper |
| Cross Section | 4 x 35 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | UV stabilised PVC, 90 deg C |
| Sheath | UV stabilised PVC compound UV-90, black |
| UV Test | ISO 4892-3, 2000 h xenon arc exposure |
| Weather Resistance | IEC 60811-401 thermal ageing after UV exposure |
| Ozone Resistance | No cracking after 96 h at 50 pphm |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 1860 kg/km |
Construction summary: Class 2 stranded bare copper with UV stabilised PVC, 90 deg C, rated 0.6/1 kV and sheathed in UV Stabilised PVC Compound UV-90. The 4 x 35 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable is intended for overhead distribution between poles, outdoor equipment connections and rooftop runs where conduit is impractical. Because the compound is stabilised against UV and ozone, the sheath does not crack at clamp points, which is the most common failure mode for ordinary PVC cable in tropical and high altitude installations.
How is UV resistance actually verified? Sheath samples are exposed in a xenon arc chamber to ISO 4892-3 for 2000 hours, which simulates several years of tropical sunlight. After exposure, tensile strength and elongation must remain above 80 percent of the original values.
Does black colour matter for UV performance? Yes. Carbon black is the most effective UV blocker for PVC, and the compound is supplied in black as standard. Coloured versions require additional stabiliser loading and are offered only after confirming the exposure conditions.
Can the cable be suspended without a messenger wire? For spans up to 20 m the cable can be supported on clamps with a catenary sag allowance. Longer spans need a separate messenger wire to avoid tensile stress on the copper conductors and sheath at the supports.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.