Product Details:
Payment & Shipping Terms:
|
| Product Name: | Weather Resistant Outdoor PVC Cable PVC Electrical Cable | Application: | Overhead Line And Outdoor Service Connection |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper | Insulation: | Weather Resistant PVC, 70 Deg C |
| Rated Voltage: | 450/750 V | Core Configuration: | 3 X 4 Mm2 |
| UV Resistance: | ISO 4892-3, 1500 H Exposure | Weather Resistance: | Outdoor Rated, Humid And Ozone Tested |
| Sheath Compound: | Weather Resistant PVC Compound WR-70 | Standard: | IEC 60227, IEC 60332-1 |
| Highlight: | Weather resistant outdoor PVC cable,Overhead 3x4mm2 service cable,Rain proof copper branch cable |
||
Service drops and outdoor branch circuits are exposed to rain, frost, condensation and sun at the same time, and a sheath that handles only one of these will fail in a season. This cable uses a weather resistant PVC compound with controlled water absorption and cold bend performance at minus 20 deg C, so installation can continue through winter without sheath cracking.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper |
| Cross Section | 3 x 4 mm2 |
| Rated Voltage | 450/750 V |
| Insulation | Weather resistant PVC, 70 deg C |
| Sheath | Weather resistant PVC compound WR-70 |
| UV Test | ISO 4892-3, 1500 h exposure |
| Rain and Humidity | IEC 60811-402 water absorption test |
| Cold Bend | Pass at minus 20 deg C |
| Standard | IEC 60227, IEC 60332-1 |
| Approx Weight | 186 kg/km |
Cable ends are sealed with heat shrink caps to stop moisture ingress during ocean freight and extended site storage.
Construction summary: Class 2 stranded bare copper with Weather resistant PVC, 70 deg C, rated 450/750 V and sheathed in Weather Resistant PVC Compound WR-70. The 3 x 4 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable connects outdoor branch circuits, small service drops, garden and yard lighting, and equipment in unheated outbuildings. Because moisture absorption is limited and the compound tolerates frost, the cable can be installed in late autumn and left in service through freeze and thaw cycles without a drop in insulation resistance.
Why check water absorption for an outdoor cable? Moisture that penetrates a sheath lowers insulation resistance and eventually causes tracking. The compound is tested to IEC 60811-402 and limits water uptake so that resistance remains stable over years of wet service.
Can the cable be installed in freezing weather? The sheath passes a cold bend test at minus 20 deg C, which allows installation in winter conditions. Below that temperature the cable should be warmed before bending to avoid micro cracks at the bend.
Is a separate earth conductor included? Yes. The three core layout carries a yellow-green earth core, so single phase service connections can be completed with one cable pull.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.