Product Details:
Payment & Shipping Terms:
|
| Product Name: | Anti UV Tropical Power Cable PVC Insulated Power Cable | Application: | Tropical Climate Heavy Duty Power Distribution |
|---|---|---|---|
| Conductor: | Class 2 Compacted Stranded Bare Copper | Insulation: | Anti UV PVC, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 4 X 70 Mm2 |
| UV Resistance: | ISO 4892-3, 3000 H Exposure | Weather Resistance: | Outdoor Rated, Humid And Ozone Tested |
| Sheath Compound: | Anti UV Heavy Duty PVC Compound AUV-90 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | Anti UV tropical power cable,4x70mm2 heavy duty PVC cable,Fungus resistant outdoor copper cable |
||
In equatorial markets the combination of intense ultraviolet radiation, year round humidity and fungal growth attacks cable sheaths from several directions at once. This four core power cable uses a heavy duty anti UV compound tested over 3000 hours of xenon arc exposure and also assessed for fungus resistance, so it holds up on open racks and coastal distribution routes where lighter constructions chalk and crack within a few years.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 compacted stranded bare copper |
| Cross Section | 4 x 70 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | Anti UV PVC, 90 deg C |
| Sheath | Anti UV heavy duty compound AUV-90, black |
| UV Test | ISO 4892-3, 3000 h exposure |
| Fungus Resistance | Pass to IEC 60068-2-10 |
| Termite Protection | Optional nylon sheath available |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 3680 kg/km |
Construction summary: Class 2 compacted stranded bare copper with Anti UV PVC, 90 deg C, rated 0.6/1 kV and sheathed in Anti UV Heavy Duty PVC Compound AUV-90. The 4 x 70 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable is specified for distribution feeders in tropical industrial estates, plantations, ports and utility networks where cables run outdoors on racks or are suspended between buildings. The optional termite resistant oversheath addresses a second regional risk, since ground level PVC sheaths are frequently damaged by termite activity in humid climates.
Why specify 3000 hours of UV testing? Equatorial sites receive far higher annual UV dose than European or North American locations, and 2000 hours of xenon arc testing may represent only a few years there. The 3000 hour rating provides a realistic service life margin for tropical deployment.
What does fungus resistance mean in practice? In hot humid climates fungi can grow on plasticiser rich surfaces and gradually degrade the sheath. Passing IEC 60068-2-10 confirms the compound supports minimal fungal growth, which keeps the surface intact over long wet seasons.
Can termite protection be added? Yes. A nylon oversheath applied over the anti UV compound is available for ground level and duct runs in regions with known termite activity, without changing the electrical ratings of the cable.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.