Product Details:
Payment & Shipping Terms:
|
| Product Name: | Outdoor UV Stabilised Solar Cable PVC Sheathed Cable | Application: | Solar Farm And Photovoltaic Plant Distribution |
|---|---|---|---|
| Conductor: | Class 2 Stranded Bare Copper | Insulation: | UV Stabilised PVC, 90 Deg C |
| Rated Voltage: | 0.6/1 KV | Core Configuration: | 5 X 10 Mm2 |
| UV Resistance: | ISO 4892-3, 2500 H Exposure | Weather Resistance: | IEC 60811-403, No Cracking After 96 H |
| Sheath Compound: | UV Stabilised Outdoor Compound OUV-90 | Standard: | IEC 60502-1, IEC 60332-1 |
| Highlight: | Outdoor UV stabilised solar cable,5x10mm2 PVC sheathed cable,PV plant distribution copper cable |
||
Solar farms expose distribution cable to full sun for twenty years on trays and in shallow trenches, and inverter compounds add ozone from switching equipment. This outdoor sheathed cable uses a UV stabilised compound verified for 2500 hours of exposure and ozone tested to IEC 60811-403, so the sheath does not crack at clamp points or near switchgear vents.
Key Features| Parameter | Specification |
|---|---|
| Conductor | Class 2 stranded bare copper |
| Cross Section | 5 x 10 mm2 |
| Rated Voltage | 0.6/1 kV |
| Insulation | UV stabilised PVC, 90 deg C |
| Sheath | Outdoor UV stabilised compound OUV-90, black |
| UV Test | ISO 4892-3, 2500 h exposure |
| Ozone Resistance | IEC 60811-403, no cracking after 96 h |
| Rodent Option | Glass yarn reinforced variant available |
| Standard | IEC 60502-1, IEC 60332-1 |
| Approx Weight | 640 kg/km |
Drum returns and cable remnants are accepted for repeat orders, which keeps scrap rates predictable for project contractors.
Construction summary: Class 2 stranded bare copper with UV stabilised PVC, 90 deg C, rated 0.6/1 kV and sheathed in UV Stabilised Outdoor Compound OUV-90. The 5 x 10 mm2 layout is supplied in coil, plywood reel or steel drum according to project handling requirements.
ApplicationsThe cable connects inverter outputs, transformer stations and auxiliary loads inside photovoltaic plants. Because it supports both direct burial and open tray installation, a single cable type can be used across the plant layout, which simplifies design and reduces the number of cable variants held in maintenance stores.
Is the cable suitable for both tray and direct burial? Yes. The sheath is rated for open air tray use with UV exposure and for direct burial in normal soil. In rocky ground a sand bed is required to prevent point loading on the sheath.
Why is ozone resistance relevant on a solar farm? Inverters and switchgear generate ozone, which attacks unstabilised polymers and causes surface cracking. Testing to IEC 60811-403 confirms no cracking after 96 hours at 50 pphm, which covers the concentrations found around inverter vents.
Can a rodent resistant version be supplied? Yes. A variant with glass yarn reinforcement under the sheath resists gnawing damage, which is useful for shallow buried runs in agricultural areas where rodent activity is high.
Installation GuidanceCable is wound on export grade wooden drums or coiled in polyethylene wrapped rolls, with drum flange marking showing type, size, length and batch number. Each batch is routine tested for conductor resistance, insulation resistance and high voltage withstand, and a mill test certificate is issued with the shipping documents. Standard packing suits 20 foot and 40 foot containers, and drum sizes are matched to the ordered length to avoid unused freight space.