Product Details:
Payment & Shipping Terms:
|
Voltage: | 0.66/1.14 | Phase: | 16mm2 To 185mm2 |
---|---|---|---|
Conducotor: | Flexible Copper | Insualtion: | Rubber |
Sheathed: | Rubber | Place Of Origin: | Shanghai |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | rubber electrical cable,rubber coated cable |
MCP Screened Rubber Sheath Cable For Excavator Power Connection
Construction:
Conductor: Flexible Class 5 Copper Conductor
Insualtion: Rubber Sheath
Screen: Copper Wire Brain Screent / Tinned Copper Wire Screen
Sheath: Rubber Sheath
China supplier 0.38/0.66 rubber sheath mining power flexible copper underground cable for mining cable
TOP TEN CABLE MANUFACTURER IN CHINA
ONE OF LARGEST CABLE MANUFACTUER IN CHINA
WITH TUV TYPE TESTING REPORT
WIDE PRODUCTS RANGE
ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONS
CNAS APPROVAL LABROTARY
Brief introduction
1 Rated voltage of the cables is divided into 6 grades, which is 0.3/0.5kV,0.38/.066kV,1.9/3.3kV,3.6/6kV,6/10kV.
2 There are allowed long-term working temperatures of the cable conductor. For the cable of U(M)CPT-0.66/1.14, U(M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14 and 1.9/3.3kV, 3.6/6kV, 6/10kV, the temperature is 90℃;for the other, it is 65℃.
3 Minimum bending radius: For the cable of U (M)CPJB-0.66/1.14, U(M)CPJR-0.66/1.14,it is 15 times of the cable diameter; for the others, it is 6 times of the cable diameters.
4 The grounding wire should be well connected with the earth.
5 The cable should be prevented from exposing to the sunshine for a long time.
Implemented standard
1 For the non-spread combustion cable, implement GB12972
2 For the flame-retardant cable, implement MT818
3 For the special mining cable(with bigger cross-section and higher voltage),implement the enterprise standard.
Type and Name:
Type | Description | Application |
MC-0.38/0.66 | Rubber flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 0.38/0.66kV | ||
MCP-0.38/0.66 | Shielded, rubber-sheathed flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 0.38/0.66kV | ||
MCP-0.66/1.14 | Shielded, rubber flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 0.38/0.66kV | ||
MCPJB-0.66/1.14 | Shielded ,monitoring and braiding reinforced type, | As the power connection used in the excavator |
rubber flexible cable for excavator | or similar equipment with rated voltage 0.66/1.14kV, | |
it can be dragged directly | ||
MCPJR-0.66/1.14 | Shielded ,monitoring and braiding reinforced type, | As the power connection used in the excavator |
rubber flexible cable for excavator | or similar equipment with rated voltage 0.66/1.14kV, | |
it must be used in the protective chain panel | ||
MCPT-0.66/1.14 | Metallic shielded rubber flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 0.66/1.14kV | ||
MCP-1.9/3.3 | Shielded rubber flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 1.9/3.3kV | ||
MCPT-1.9/3.3 | Metallic shielded rubber flexible cable for excavator | As the power connection used in the excavator |
or similar equipment with rated voltage 1.9/3.3kV | ||
MCPTJ-1.9/3.3 | Metallic shielded, monitoring type, rubber flexible cable for | As the power connection used in the excavator |
excavator | or similar equipment with rated voltage 1.9/3.3kV | |
MY-0.38/0.66 | Movable rubber flexible cable for mining | As the power connection used in the mining |
machine with rated voltage 1.9/3.3kV | ||
MYP-0.38/0.66 | Movable shield rubber flexible cable for mining | As the power connection used in the mining |
machine with rated voltage 0.38/0.66kV | ||
MYP-0.66/1.14 | Movable shield rubber flexible cable for mining | As the power connection used in the mining |
machine with rated voltage 0.66/1.14kV | ||
MYPJ-3.6/6 | Monitoring movable shield rubber flexible cable for mining | As the power connection used in the mining t |
ransformer and similar equipment with rated voltage3.6/6kV | ||
MYPTJ-3.6/6 | Metallic shielded monitoring type movable | As the power connection used in the mining |
rubber flexible cable | transformer and similar equipment with rated voltage3.6/6kV | |
MYP-3.6/6 | Movable shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
the min. environment temperature is-20℃ | ||
MYPT-3.6/6 | Movable metallic shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
the min. environment temperature is-20℃ | ||
MYPD-3.6/6 | Movable shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
the min. environment temperature is-40℃ | ||
MYPTD-3.6/6 | Movable metallic shield rubber flexible cable for mining | Mining equipment with rated voltage 3.6/6kV |
the min. environment temperature is-40℃ | ||
MZ-0.3/0.5 | Driller cable for mining | As the power connection of driller with rated |
voltage 0.3/0.5kV | ||
MZP-0.3/0.5 | Driller shielded cable for mining | As the power connection of driller with rated |
voltage 0.3/0.5kV | ||
MYQ-0.3/0.5 | Movable light-type rubber flexible cable for mining | Lighting in the mine, as the power connection |
of the interlock and control signals | ||
used in the transport machine and equipment |
We are focus
We specialize in manufacturing and exporting many kinds of wire and cables. We have professional engineers, skilled workers, advanced manufacturing equipments and scientific management.
Our commitment to service and our abilities to provide the ideal solutions for your application is the basis for our growth. When you come to Ninggang, you can expect personalized attention. Our experts will help to identify, solve and supply your flexible cable needs and requirements- for any environment.
Characteristics
1. Rated power-frequency voltage U0/U: 450/750V, 300/500V and 200/200V.
2. Maximum permitted operating temperature of conductor is 60°C.
3. Permitted lowest working temperature is -35°C.
4. Cables can be used at places contaminated by mineral oil and fuel oil.
CorexSize | Insulation Thickness | Overall diameter(mm) MCP-0.66/1.44 |
||||
Phase | Grounding | Control | Phase | Thickness | Min | Max |
3x25 | 1x6 | 3x4 | 2 | 6 | 41 | 47 |
3x35 | 1x6 | 3x4 | 2 | 6 | 44 | 51 |
3x50 | 1x10 | 3x6 | 2.2 | 7 | 51.5 | 59 |
3x70 | 1x16 | 3x6 | 2.2 | 7 | 56 | 63.5 |
3x95 | 1x25 | 3x10 | 2.4 | 7 | 62 | 70.5 |
3x120 | 1x25 | 3x10 | 2.6 | 7 | 66.5 | 75.5 |
3x150 | 1x35 | 3x10 | 2.6 | 7 | 71.5 | 80.5 |
3x185 | 1x35 | 3x10 | 2.8 | 7 | 77 | 85.5 |