Product Details:
Payment & Shipping Terms:
|
Product Name: | Steel Armoured Cable | Conductor: | Stranded Copper Conductor, Cl.2 As Per IEC 60228 |
---|---|---|---|
Insulation: | XLPE(cross-linked Polyethylene) Rated At 90 OC | Inner Sheath: | PVC |
Shield: | Copper Tape | Armored: | Galvanized Steel Wire |
Sheath: | PVC Or FR-PVC Type ST2 To IEC 60502, Black(color Could Be Customized | Usage: | Outdoor |
High Light: | IEC 60228 armoured copper cable,XLPE steel armoured cable |
XLPE Insulated Armored Power Cable Used for Underground Transmission
Armored Power Cable Construction
Conductor : Stranded copper conductor, Cl.2 as per IEC 60228
Insulation : XLPE(cross-linked polyethylene) rated at 90 OC
Inner sheath : PVC
Armored :Galvanized Steel Wire.
Sheath : PVC or FR-PVC type ST2 to IEC 60502, black(color could be customized
Armored Power Cable Application
The steel wire armored cable can be used for underground installation directly,for the civil construction, commercial buildings.
Rated voltage:0.6/1KV
Maximum Conductor Temperature: under normal (90 OC), emergency (130OC) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 12 x cable O.D for multi core
Armored Power Cable Standard
International: IEC 60502, IEC 60228,
China: GB/T 12706, (GB/T 12706.1-2008
Other standards such as BS,DIN and ICEA upon request
Armored Power Cable Certificate
CE, RoHS, , KEMA and more others at request
Commercial Items: MOQ: 1000m
Price Term: FOB shanghai or CIF as request
Payment terms: 30% T/T before production, 70% T/T before delivery
Packing : Wooden Iron drum
Armored Power Cable Specifications
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness | Inner Sheath Thickness | Steel Wire Dia. | Sheath Thickness | Approx. O.D. | Approx. Weight |
Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | ||
mm2 | pc/mm | mm | mm | mm | mm | Lower Limit (mm) | Upper Limit (mm) | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
1 × 25 | 7/2.14 | 0.9 | 1.0 | 1.25 | 1.8 | 15.9 | 16.5 | 653 | 0.727 | 3.5 | 130 | 155 |
1 × 35 | 7/2.52 | 0.9 | 1.0 | 1.25 | 1.8 | 16.9 | 17.5 | 775 | 0.524 | 3.5 | 160 | 185 |
1 × 50 | 10/2.52 | 1.0 | 1.0 | 1.25 | 1.8 | 18.1 | 18.7 | 936 | 0.387 | 3.5 | 195 | 220 |
1 × 70 | 14/2.52 | 1.1 | 1.0 | 1.25 | 1.8 | 20.0 | 20.6 | 1175 | 0.268 | 3.5 | 245 | 270 |
1 × 95 | 19/2.52 | 1.1 | 1.0 | 1.60 | 1.8 | 22.0 | 22.6 | 1556 | 0.193 | 3.5 | 300 | 320 |
1 × 120 | 24/2.52 | 1.2 | 1.0 | 1.60 | 1.8 | 23.6 | 24.4 | 1822 | 0.153 | 3.5 | 350 | 365 |
1 × 150 | 30/2.52 | 1.4 | 1.0 | 1.60 | 1.8 | 25.3 | 26.1 | 2156 | 0.124 | 3.5 | 400 | 410 |
1 × 185 | 37/2.52 | 1.6 | 1.0 | 1.60 | 1.8 | 27.4 | 28.2 | 2536 | 0.0991 | 3.5 | 465 | 465 |
1 × 240 | 48/2.52 | 1.7 | 1.0 | 1.60 | 1.9 | 29.9 | 30.7 | 3110 | 0.0754 | 3.5 | 550 | 540 |
1 × 300 | 61/2.52 | 1.8 | 1.0 | 2.00 | 2.0 | 33.1 | 33.9 | 3947 | 0.0601 | 3.5 | 635 | 610 |
1 × 400 | 61/2.97 | 2.0 | 1.2 | 2.00 | 2.2 | 37.5 | 38.3 | 5046 | 0.0470 | 3.5 | 745 | 695 |
2 × 2.5 | 1/1.78 | 0.7 | 1.2 | 47/2.0 | 1.4 | 10.8 | 12.5 | 151 | 7.41 | 3.5 | 26 | 35 |
2 × 4 | 1/2.25 | 0.7 | 1.2 | 50/2.0 | 1.8 | 11.9 | 13.6 | 198 | 4.61 | 3.5 | 34 | 45 |
2 × 6 | 1/2.76 | 0.7 | 1.4 | 50/2.5 | 1.8 | 13.2 | 14.5 | 250 | 3.08 | 3.5 | 43 | 57 |
2 × 10 | 7/1.38 | 0.7 | 1.4 | 52/2.5 | 1.8 | 15.0 | 16.7 | 374 | 1.83 | 3.5 | 60 | 77 |
2 × 16 | 7/1.78 | 0.7 | 1.0 | 1.60 | 1.8 | 17.1 | 18.8 | 518 | 1.15 | 3.5 | 83 | 105 |
2 × 25 | 7/2.14 | 0.9 | 1.0 | 1.60 | 1.8 | 19.8 | 21.5 | 772 | 0.727 | 3.5 | 105 | 125 |
2 × 35 | 7/2.52 | 0.9 | 1.0 | 1.60 | 1.8 | 21.8 | 23.5 | 1006 | 0.524 | 3.5 | 125 | 155 |
2 × 50 | 10/2.52 | 1.0 | 1.0 | 32/1.6 | 1.8 | 19.8 | 21.5 | 1365 | 0.387 | 3.5 | 160 | 185 |
2 × 70 | 14/2.52 | 1.1 | 1.0 | 36/1.6 | 1.8 | 21.0 | 22.7 | 1872 | 0.268 | 3.5 | 200 | 225 |
2 × 95 | 19/2.52 | 1.1 | 1.0 | 42/1.6 | 1.8 | 24.2 | 25.9 | 2475 | 0.193 | 3.5 | 245 | 270 |
2 × 120 | 24/2.52 | 1.2 | 1.0 | 46/1.6 | 1.8 | 26.6 | 28.3 | 3089 | 0.153 | 3.5 | 285 | 310 |
2 × 150 | 30/2.52 | 1.4 | 1.0 | 46/1.6 | 1.9 | 29.8 | 31.5 | 3834 | 0.124 | 3.5 | 325 | 345 |
2 × 185 | 37/2.52 | 1.6 | 1.0 | 42/2.0 | 2.0 | 32.4 | 34.1 | 3943.0 | 0.0991 | 3.5 | 375 | 390 |
2 × 240 | 48/2.52 | 1.7 | 1.2 | 49/2.0 | 2.2 | 39.6 | 41.3 | 5135.0 | 0.0754 | 3.5 | 440 | 450 |
2× 300 | 61/2.52 | 1.8 | 1.2 | 52/2.0 | 2.3 | 40.8 | 42.5 | 6436.0 | 0.0601 | 3.5 | 505 | 515 |
3 × 25 | 7/2.14 | 0.9 | 1.0 | 1.60 | 1.8 | 26.2 | 28.1 | 1707 | 0.727 | 3.5 | 105 | 125 |
3 × 35 | 7/2.52 | 0.9 | 1.0 | 1.60 | 1.9 | 28.5 | 30.4 | 2071 | 0.524 | 3.5 | 125 | 155 |
3 × 50 | 10/2.52 | 1.0 | 1.0 | 1.60 | 1.8 | 28.0 | 29.9 | 2405 | 0.387 | 3.5 | 160 | 185 |
3 × 70 | 14/2.52 | 1.1 | 1.0 | 1.60 | 2.0 | 31.7 | 33.6 | 3084 | 0.268 | 3.5 | 200 | 225 |
3 × 95 | 19/2.52 | 1.1 | 1.2 | 2.00 | 2.1 | 36.4 | 38.3 | 4126 | 0.193 | 3.5 | 245 | 270 |
3 × 120 | 24/2.52 | 1.2 | 1.2 | 2.00 | 2.2 | 39.2 | 41.1 | 4901 | 0.153 | 3.5 | 285 | 310 |
3 × 150 | 30/2.52 | 1.4 | 1.2 | 2.50 | 2.4 | 45.3 | 47.2 | 6365 | 0.124 | 3.5 | 325 | 345 |
3 × 185 | 37/2.52 | 1.6 | 1.4 | 2.50 | 2.5 | 49.2 | 51.1 | 7555 | 0.0991 | 3.5 | 375 | 390 |
3 × 240 | 48/2.52 | 1.7 | 1.4 | 2.50 | 2.7 | 54.0 | 55.9 | 9284 | 0.0754 | 3.5 | 440 | 450 |
3 × 300 | 61/2.52 | 1.8 | 1.6 | 2.50 | 2.9 | 59.5 | 61.4 | 11226 | 0.0601 | 3.5 | 505 | 515 |
3 × 400 | 61/2.97 | 2.0 | 1.8 | 3.15 | 3.4 | 74.5 | 76.4 | 15714 | 0.0470 | 3.5 | 570 | 575 |
4 × 10 | 7/1.38 | 0.7 | 1.2 | 46/2.0 | 1.8 | 17.2 | 18.9 | 501 | 1.83 | 3.5 | 60 | 77 |
4 × 16 | 7/1.78 | 0.7 | 1.2 | 37/1.6 | 1.8 | 19.7 | 21.4 | 1550 | 1.15 | 3.5 | 83 | 105 |
4 × 25 | 7/2.14 | 0.9 | 1.2 | 46/2.5 | 1.8 | 23.0 | 24.7 | 1160 | 0.727 | 3.5 | 105 | 125 |
4 × 70 | 14/2.52 | 1.1 | 1.6 | 62/2.5 | 1.8 | 26.6 | 28.3 | 3975 | 0.268 | 3.5 | 200 | 225 |
4 × 150 | 30/2.52 | 1.4 | 1.9 | 70/3.15 | 2.2 | 38.1 | 39.8 | 6238 | 0.124 | 3.5 | 325 | 345 |
Armoured Cable Wiring Details
PACKING AND SHIPPING
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum. The packing material is depended on the weight and size of cable. After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight. The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.
Services
♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.
♦ We accept OEM. The cable size and material are customized.Ur own logo and own design are welcome. We will produce according to your requirement and description;
♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.