Product Details:
Payment & Shipping Terms:
|
Conductor: | Copper | Insulation: | XLPE |
---|---|---|---|
Wrapping Tape: | LSOH BendingTape | Sheath: | LSOH |
Rated Voltage: | LV And MV | Cores No.: | 1-5 Cores |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | fire retardant cable,flame resistant cable |
FRC Fire Resistant XLPE insulation LSOH sheath Power cable
Construction
1 Conductor: Compactstranded copperconductor, Cl.2 as perlEC60228
(11 MicaTape
③lnsulation:XLPE(cross-linkedpolyethylene)ratedat90°C
(1111 Filler
(5: Wrapping Tape: LSOH BendingTape
⑥Sheath:LSOH,blackorothercolors,asperlEC60332,60502-1
CodeDesignation
YJ:XLPEinsulation Y: LSOH sheath
Applications
Forlaying indoors and outdoors.Able to bear certain traction during installation, but not extemal mechanical forces. Laying single core cable in magnetic ducts is not allowed.
Standards
lnternational: IEC60502. IEC60228, (lEC60332-3forFRcableonly) China: GB/T12706,(GB/T18380-3 for FR cable only)
Other standards such as BS, DIN and lCEAupon request
Technical data
Rated voltage: 0.6/ 1㎸
Maximum Conductor Temperature: under normal (90°C), emergency(130°C) or short circuit no more than 5 s(250°C) conditions Min.Ambient Temp.-15°C,lnstallationTemp.0°C