Product Details:
Payment & Shipping Terms:
|
How Many Core: | One Core | Insulation: | Cross-linked XLPE |
---|---|---|---|
Outer Sheath: | PVC | Conductor: | Stranded Copper Class2 |
Conductor Temp:: | 90 Degree | Sample: | Free |
Insulation Color: | Natural | Corporation: | Shenghua Group |
Brand: | Sh Cable | ||
Highlight: | 1 Core XLPE Insulated Power Cable,PVC sheath XLPE Insulated Power Cable,IEC xlpe insulated pvc sheathed cable |
1 Core High Voltage Power Cable XLPE Insulation PVC Outer sheath 1Cx95SQMM Best Supplier
Applications: XLPE Insulated Cable is used as power distribution and transmission line at rated voltage 26/35kV.
Construction:
Conductor | Copper Conductor as per IEC 60228,Class 2 |
Circular or Shaped conductor | |
Flexible conductor(class 5) optional. | |
Insulation | XLPE (Cross-Linked Polyethylene) rated at 90℃,many color optional |
Metallic Screen optional | Copper tape or copper wires braiding optional |
Sheath | PVC or FR-PVC type ST2 to IEC 60502, black or red or customization |
Ordering Advice
Rated Voltage
Application Standard: IEC/BS/UL/GB
Number of Cores
Conductor Size & Construction
Type of Insulation
Armored or unarmored. If armor, the armor type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
Technical data: Rated voltage:26/35kV Medium Voltage
Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core without armor
15 x cable O.D for multi core without armor
15 x cable O.D for single core with armor
12 x cable O.D for multi core with armor
Standards: International: IEC 60502-2, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS, DIN, VDE and ICEA upon request
Technical parameter:
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness | Sheath Thickness | Approx. O.D. |
Approx. Weight |
Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | pc/mm | mm | mm | mm | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
1 × 50 | 10/2.52 | 10.5 | 2.2 | 39.0 | 1758 | 0.387 | 91 | 220 | 215 |
1 × 70 | 14/2.52 | 10.5 | 2.4 | 41.0 | 2038 | 0.268 | 91 | 270 | 265 |
1 × 95 | 19/2.52 | 10.5 | 2.4 | 42.0 | 2355 | 0.193 | 91 | 330 | 315 |
1 × 120 | 24/2.52 | 10.5 | 2.4 | 44.0 | 2666 | 0.153 | 91 | 375 | 360 |
1 × 150 | 30/2.52 | 10.5 | 2.5 | 45.0 | 3031 | 0.124 | 91 | 425 | 400 |
1 × 185 | 37/2.52 | 10.5 | 2.5 | 47.0 | 3427 | 0.0991 | 91 | 485 | 455 |
1 × 240 | 48/2.52 | 10.5 | 2.6 | 49.0 | 4070 | 0.0754 | 91 | 560 | 525 |
1 × 300 | 61/2.52 | 10.5 | 2.7 | 51.0 | 4748 | 0.0601 | 91 | 650 | 595 |
1 × 400 | 61/2.97 | 10.5 | 2.8 | 55.0 | 5801 | 0.0470 | 91 | 760 | 680 |
1 × 500 | 61/3.23 | 10.5 | 2.9 | 58.0 | 6623 | 0.0366 | 91 | 875 | 775 |
1 × 630 | 61/3.50 | 10.5 | 3 | 62.0 | 5211 | 0.0283 | 91 | 1000 | 875 |
1 × 800 | 91/3.20 | 10.5 | 3.1 | 68.0 | 10014 | 0.0221 | 91 | 1130 | 970 |
1 × 1000 | 91/3.75 | 10.5 | 3.3 | 72.0 | 12078 | 0.0176 | 91 | 1250 | 1060 |
3 × 50 | 10/2.52 | 10.5 | 3.7 | 81.0 | 6728 | 0.387 | 91 | 185 | 200 |
3 × 70 | 14/2.52 | 10.5 | 3.8 | 84.0 | 7581 | 0.268 | 91 | 230 | 250 |
3 × 95 | 19/2.52 | 10.5 | 3.9 | 88.0 | 8630 | 0.193 | 91 | 280 | 300 |
3 × 120 | 24/2.52 | 10.5 | 4.0 | 91.0 | 9688 | 0.153 | 91 | 310 | 330 |
3 × 150 | 30/2.52 | 10.5 | 4.1 | 95.0 | 11017 | 0.124 | 91 | 360 | 380 |
3 × 185 | 37/2.52 | 10.5 | 4.2 | 98.0 | 12390 | 0.0991 | 91 | 400 | 425 |
3 × 240 | 48/2.52 | 10.5 | 4.4 | 103.0 | 14427 | 0.0754 | 91 | 470 | 490 |
3 × 300 | 61/2.52 | 10.5 | 4.5 | 108.0 | 15940 | 0.0601 | 91 | 540 | 555 |
3 × 400 | 61/2.97 | 10.5 | 4.8 | 116.0 | 19346 | 0.0470 | 91 | 610 | 625 |