Product Details:
Payment & Shipping Terms:
|
Type: | XLPE Insulated Power Cable | Feature: | Low Voltage |
---|---|---|---|
Conductor Screen:: | Semi-conductor | Sample: | Free |
Insulation Color: | Yellow,Blue | Advnatage: | Abrasion Resistance |
Sheath: | PVC Or FR-PVC Type ST2 To IEC 60502, Black | Screen: | Copper Tape |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | 21/35kV XLPE power cable,earthquake-resistant power grid cable,XLPE insulated high voltage cable |
Attribute | Value |
---|---|
Type | XLPE Insulated Power Cable |
Feature | Low Voltage |
Conductor Screen | Semi-conductor |
Sample | Free |
Insulation Color | Yellow, Blue |
Advantage | Abrasion Resistance |
Sheath | PVC or FR-PVC type ST2 to IEC 60502, black |
Screen | Copper tape |
Corporation | Shenghua Group |
Brand | SH Cable |
Shenghua's 21/35kV XLPE Insulated Power Cable engineers triple-layer defense architecture to withstand seismic shifts, chemical corrosion, and thermal runaway—proven in 60+ countries for grids where failure is not an option.
Threat Scenario | Shenghua Solution | Verification Data |
---|---|---|
Underground Landslide | Armored variant (SWA) + torsion-resistant filler | Min. bending radius=12×OD; 3.5kV/5min dielectric test |
Arctic Cable Heave | Arctic-grade LSOH sheath (-60°C flexibility) | Passed IEC 62930 cold bend test at -40°C |
Data Center Overload | 4×400mm² config with 0.0778Ω/km resistance | 445A soil current; 18% lower losses vs. ISO averages |
The product is used in power transmission and distribution line at voltage up. It does not only have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress.
Rated voltage: 21/35(36)kV
Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
Min. Ambient Temp.: 0°C, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core, 15 x cable O.D for multi core
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness | Sheath Thickness | Approx. O.D. | Approx. Weight | Max. D.C Resistance of Conductor (20°C) | Testing Voltage A.C | Current Rating In air (A) | Current Rating In soil(A) |
---|---|---|---|---|---|---|---|---|---|
4 × 4 | 1/2.25 | 0.7 | 1.8 | 13.0 | 155 | 7.41 | 3.5 | 27 | 36 |
4 × 6 | 1/2.76 | 0.7 | 1.8 | 14.0 | 184 | 4.61 | 3.5 | 35 | 46 |
4 × 10 | 7/1.38 | 0.7 | 1.8 | 17.0 | 258 | 3.08 | 3.5 | 47 | 59 |
4 × 16 | 7/1.78 | 0.7 | 1.8 | 20.0 | 366 | 1.91 | 3.5 | 64 | 80 |
4 × 25 | 7/2.14 | 0.9 | 1.8 | 23.0 | 540 | 1.200 | 3.5 | 82 | 100 |
4 × 35 | 7/2.52 | 0.9 | 1.8 | 25 | 686 | 0.868 | 3.5 | 100 | 120 |
4 × 50 | 10/2.52 | 1.0 | 1.8 | 23 | 907 | 0.641 | 3.5 | 125 | 145 |
4 × 70 | 14/2.52 | 1.1 | 1.8 | 27 | 1192 | 0.443 | 3.5 | 155 | 175 |
4 × 95 | 19/2.52 | 1.1 | 1.9 | 31 | 1598 | 0.320 | 3.5 | 200 | 210 |
4 × 120 | 24/2.52 | 1.2 | 2.0 | 33 | 1949 | 0.253 | 3.5 | 220 | 240 |
4 × 150 | 30/2.52 | 1.4 | 2.2 | 38 | 2517 | 0.206 | 3.5 | 250 | 270 |
4 × 185 | 37/2.52 | 1.6 | 2.3 | 42 | 3091 | 0.1640 | 3.5 | 295 | 305 |
4 × 240 | 48/2.52 | 1.7 | 2.5 | 47 | 3825 | 0.1250 | 3.5 | 345 | 355 |
4 × 300 | 61/2.52 | 1.8 | 2.6 | 52 | 4830 | 0.1000 | 3.5 | 395 | 400 |
4 × 400 | 61/2.97 | 2.0 | 3.1 | 66 | 5840 | 0.0778 | 3.5 | 445 | 445 |