Product Details:
Payment & Shipping Terms:
|
| Product Name: | Fire Resistant Mica Tape XLPE Insulated Power Cable | Application: | Fire Alarm, Sprinkler Pump And Smoke Extraction Feeders |
|---|---|---|---|
| Conductor Material: | Class 2 Stranded Annealed Copper, IEC 60228 | Rated Voltage: | 0.6/1 KV (Um 1.2 KV) |
| Core And Cross Section: | 3 X 95 Mm2 | Insulation Material: | XLPE Over Mica Tape Fire Barrier |
| Fire Performance: | Circuit Integrity 90 Minutes To IEC 60331-21 | Armour Type: | Double Steel Tape Armour (STA) |
| Outer Sheath: | Black PVC, Flame Retardant | Design Standard: | IEC 60502-1, IEC 60331 |
| Highlight: | Copper XLPE Insulated Power Cable,3x95mm2 XLPE Insulated Power Cable,Fire Resistant XLPE Insulated Power Cable |
||
When a building fire starts, the circuits that matter are the ones feeding alarms, sprinkler pumps, pressurisation fans and smoke extraction. This three core 95mm2 cable keeps those circuits live by wrapping every copper conductor in overlapping mica tape before the XLPE extrusion. Under flame the mica turns into a ceramic shell that holds the conductor apart, so the circuit keeps delivering current for ninety minutes in the IEC 60331-21 test.
Around the insulated cores sits a double steel tape armour that protects the assembly from mechanical damage during building works and provides a stable earth path. The flame retardant PVC oversheath limits flame spread along vertical risers, which is why the combination of mica tape, XLPE and STA armour is the standard choice for life safety feeders in high rise and industrial projects.
Because the fire barrier sits directly on the conductor, protection does not depend on the sheath surviving. That is the key difference from flame retardant cable, which only slows flame spread and offers no circuit integrity guarantee once the insulation is attacked.
| Parameter | Specification |
|---|---|
| Cable Construction | Copper / mica tape barrier / XLPE / STA armour / FR PVC sheath |
| Rated Voltage | 0.6/1 kV, Um 1.2 kV |
| Conductor | Class 2 stranded annealed copper to IEC 60228 |
| Cross Section | 3 x 95 mm2 |
| Fire Barrier | Overlapping mica tape on each core |
| Circuit Integrity | 90 minutes to IEC 60331-21 |
| Armour | Double steel tape, hot dip galvanised |
| Flame Spread | IEC 60332-3 category C |
| Routine Test | 3.5 kV AC for 5 minutes |
| Packing | 500 m wooden drum |
Each batch is flame tested and sampled for circuit integrity at a third party laboratory, with conductor resistance and insulation thickness recorded per drum. Our engineers can review your fire strategy drawing and confirm which circuits require ninety minute rating and where a lower cost flame retardant cable is acceptable. A fire resistant mica tape barrier plus STA armour is the combination most fire consultants specify for pumped feeders, and this three core 95mm2 copper cable meets that brief.
Fire safety feeders are usually ordered against a drawing that lists circuit integrity minutes, so we ask for the fire strategy extract rather than only a cable size. This fire resistant cable is produced in batches with the mica tape width and overlap recorded, and each drum carries a test reference that ties back to the IEC 60331 report. Glands, fire barriers and sealing putty can be supplied in the same delivery, which keeps the installation compliant and the handover file complete.
Q: How is fire resistant cable different from flame retardant cable?
A: Flame retardant cable slows flame spread but does not promise a working circuit. This fire resistant cable uses mica tape to keep the conductor insulated during the fire itself.
Q: Does the 3x95mm2 cable need special glands?
A: Use steel tape armour glands with an earth tag so the armour is bonded at both ends; we can quote matching kits with the cable.
Q: Can the mica tape barrier be verified on site?
A: Yes. The mica layer is visible on a cross section and we supply a sample piece plus the IEC 60331 report with every drum.
Q: What ambient temperature is assumed for the ninety minute rating?
A: The IEC 60331-21 test uses a flame at over 750 C for ninety minutes with rated voltage applied, which covers typical building fire conditions.
Q: Can the fire resistant cable be ordered with matching glands and fire barriers?
A: Yes, we supply steel tape armour glands, fire rated sealing putty and barrier plates alongside the mica tape cable so the whole feeder is compliant at handover.
Send your fire strategy extract and feeder list, and we will confirm which circuits need this fire resistant mica tape construction, then quote cable and glands together.