Fire Resistant Mica Tape Screen 3x95mm2 Copper XLPE Insulated Power Cable

Certification
China Shanghai Shenghua Cable (Group) Co., Ltd. certification
China Shanghai Shenghua Cable (Group) Co., Ltd. certification
Nice supplier, fast speed response, fast delivery time, high quality product. I am lucky to find you!

—— John Smith

We have been to working with together for 5 years, they are good supplier and good freinds, our honor to work with them.

—— Mohamed Rebai

I'm very pleased with the service of this company,I believe that their business will be better and better.

—— Daniel

Your professional presentation and service that you gave us merited a standing ovation. Shenghua should have more bright future.

—— Rendell Brewster

Шенгхуа іс а цредібле энтерпрісэ, ве хве эстаблішед цооператыён фор з ерс анд віл кеп лонг тэрм цооператыён.

—— KHADBAATAR

I'm Online Chat Now

Fire Resistant Mica Tape Screen 3x95mm2 Copper XLPE Insulated Power Cable

China Fire Resistant Mica Tape Screen 3x95mm2 Copper XLPE Insulated Power Cable supplier
Fire Resistant Mica Tape Screen 3x95mm2 Copper XLPE Insulated Power Cable supplier

Large Image :  Fire Resistant Mica Tape Screen 3x95mm2 Copper XLPE Insulated Power Cable

Product Details:

Place of Origin: Shanghai, China
Brand Name: Shenghua
Certification: ISO 9001:2015, CCC, CE
Model Number: NH-YJV22-0.6/1kV-3x95

Payment & Shipping Terms:

Minimum Order Quantity: 500 Meters
Price: USD 9.80 - 13.50 / Meter
Packaging Details: 500 m per wooden drum with fire test certificate attached to the drum label
Delivery Time: 18-25 working days for production
Payment Terms: T/T, L/C at sight, Western Union
Supply Ability: 250000 Meters per Month
Detailed Product Description
Product Name: Fire Resistant Mica Tape XLPE Insulated Power Cable Application: Fire Alarm, Sprinkler Pump And Smoke Extraction Feeders
Conductor Material: Class 2 Stranded Annealed Copper, IEC 60228 Rated Voltage: 0.6/1 KV (Um 1.2 KV)
Core And Cross Section: 3 X 95 Mm2 Insulation Material: XLPE Over Mica Tape Fire Barrier
Fire Performance: Circuit Integrity 90 Minutes To IEC 60331-21 Armour Type: Double Steel Tape Armour (STA)
Outer Sheath: Black PVC, Flame Retardant Design Standard: IEC 60502-1, IEC 60331
Highlight:

Copper XLPE Insulated Power Cable

,

3x95mm2 XLPE Insulated Power Cable

,

Fire Resistant XLPE Insulated Power Cable

Product Overview

When a building fire starts, the circuits that matter are the ones feeding alarms, sprinkler pumps, pressurisation fans and smoke extraction. This three core 95mm2 cable keeps those circuits live by wrapping every copper conductor in overlapping mica tape before the XLPE extrusion. Under flame the mica turns into a ceramic shell that holds the conductor apart, so the circuit keeps delivering current for ninety minutes in the IEC 60331-21 test.

Around the insulated cores sits a double steel tape armour that protects the assembly from mechanical damage during building works and provides a stable earth path. The flame retardant PVC oversheath limits flame spread along vertical risers, which is why the combination of mica tape, XLPE and STA armour is the standard choice for life safety feeders in high rise and industrial projects.

Because the fire barrier sits directly on the conductor, protection does not depend on the sheath surviving. That is the key difference from flame retardant cable, which only slows flame spread and offers no circuit integrity guarantee once the insulation is attacked.

Technical Specifications

Parameter Specification
Cable Construction Copper / mica tape barrier / XLPE / STA armour / FR PVC sheath
Rated Voltage 0.6/1 kV, Um 1.2 kV
Conductor Class 2 stranded annealed copper to IEC 60228
Cross Section 3 x 95 mm2
Fire Barrier Overlapping mica tape on each core
Circuit Integrity 90 minutes to IEC 60331-21
Armour Double steel tape, hot dip galvanised
Flame Spread IEC 60332-3 category C
Routine Test 3.5 kV AC for 5 minutes
Packing 500 m wooden drum

Key Advantages

  • Mica tape barrier keeps the circuit live for ninety minutes while the fire is still burning.
  • Double steel tape armour protects the mica layer from knocks during second fix works.
  • 95mm2 copper supports pump and fan starting currents without excessive voltage dip.
  • Flame retardant sheath limits vertical flame travel in risers and shafts.
  • Fire test reports issued per production batch for the building handover file.

Typical Applications

  • Sprinkler pumps, fire pumps and jockey pump feeders
  • Fire alarm panel supplies and smoke extraction fans
  • Pressurisation fan and lift homing circuits
  • Emergency lighting and escape route signage
  • Petrochemical and steel plant safety shutdown loops

Quality Assurance and Test Data

Each batch is flame tested and sampled for circuit integrity at a third party laboratory, with conductor resistance and insulation thickness recorded per drum. Our engineers can review your fire strategy drawing and confirm which circuits require ninety minute rating and where a lower cost flame retardant cable is acceptable. A fire resistant mica tape barrier plus STA armour is the combination most fire consultants specify for pumped feeders, and this three core 95mm2 copper cable meets that brief.

Ordering and Delivery Notes

Fire safety feeders are usually ordered against a drawing that lists circuit integrity minutes, so we ask for the fire strategy extract rather than only a cable size. This fire resistant cable is produced in batches with the mica tape width and overlap recorded, and each drum carries a test reference that ties back to the IEC 60331 report. Glands, fire barriers and sealing putty can be supplied in the same delivery, which keeps the installation compliant and the handover file complete.

Selection and Test Summary

  • A fire resistant mica tape run is only as strong as its terminations, so we supply the gland kit that matches the 3x95mm2 copper section.
  • Where the riser is long, the STA armoured version keeps the XLPE Insulated Power Cable stable against building movement.
  • Our fire resistant mica tape line records tape width and overlap per batch, and the XLPE Insulated Power Cable leaves the plant with that reference.
  • For a lift lobby or a pump room the STA armoured construction also protects the 3x95mm2 copper during second fix works.
  • For a sprinkler pump panel the fire resistant mica tape construction keeps the feeder live even when the pump room is smoke logged.
  • We can supply a short sample of the STA armoured cable so your contractor can trial the gland and earth tag before the full order.

Frequently Asked Questions

Q: How is fire resistant cable different from flame retardant cable?
A: Flame retardant cable slows flame spread but does not promise a working circuit. This fire resistant cable uses mica tape to keep the conductor insulated during the fire itself.

Q: Does the 3x95mm2 cable need special glands?
A: Use steel tape armour glands with an earth tag so the armour is bonded at both ends; we can quote matching kits with the cable.

Q: Can the mica tape barrier be verified on site?
A: Yes. The mica layer is visible on a cross section and we supply a sample piece plus the IEC 60331 report with every drum.

Q: What ambient temperature is assumed for the ninety minute rating?
A: The IEC 60331-21 test uses a flame at over 750 C for ninety minutes with rated voltage applied, which covers typical building fire conditions.

Q: Can the fire resistant cable be ordered with matching glands and fire barriers?
A: Yes, we supply steel tape armour glands, fire rated sealing putty and barrier plates alongside the mica tape cable so the whole feeder is compliant at handover.

Send your fire strategy extract and feeder list, and we will confirm which circuits need this fire resistant mica tape construction, then quote cable and glands together.

Contact Details
Shanghai Shenghua Cable (Group) Co., Ltd.

Contact Person: Mayling Zhao

Tel: +86 15901866124

Send your inquiry directly to us (0 / 3000)