Product Details:
Payment & Shipping Terms:
|
Conductor Material: | Compact Stranded Copper | Insulation Material: | Cross-Linked XLPE |
---|---|---|---|
Standard: | IEC60502-2 | Shield Material: | Copper Tape |
Jacket Material: | PVC-ST2 | Max.Conductor Tepm: | 90 Degree |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | IEC 60502 YJLV Aluminum Power Cables,Shenghua YJLV Aluminum Power Cables |
Medium Voltage Single-Core XLPE Insulated Power Cable From 25 sqmm to 800sqmm
Engineered for Solar Farms, Grid Upgrades & Harsh Environments
As global renewable energy investments surge past $2 trillion annually (IEA 2025), project developers face a critical challenge: balancing budget constraints with uncompromising performance. Shenghua Power Cable solves this equation with YJLV Series Aluminum Conductor Cables—IEC 60502-certified solutions that reduce costs by 40% versus copper cables while matching current-carrying capacity. Validated in 850+ MW of solar installations and rural grid modernization projects, our aluminum-core technology redefines value engineering for sustainable infrastructure.
Photovoltaic Farms:
Rural Grid Modernization:
Parameter | Shenghua YJLV Series | Standard Copper Cables |
---|---|---|
Cost per Meter | $0.38 (150mm² 3-core) | $0.63 (equivalent Cu cable) |
Max Operating Temp | 90°C (XLPE insulation) | 90°C |
Lifespan | 25+ years | 20–30 years |
Short-Circuit Withstand | 5 sec @ 250°C | 5 sec @ 250°C |
Source: Shenghua IEC 60502 test data, 2024 |
Construction
Conductor: Annealed Aluminum Conductor as per IEC 60228
≤ 6mm2 solid (class 1) or stranded (class 2)
> 6mm2 stranded (class 2)
Flexible conductor (class 5) optional.
Insulation: XLPE (Cross-Linked Polyethylene) rated at 90℃
Metallic Screen optional: Copper tape or copper wires screen optional
Sheath: PVC or FR-PVC type ST2 to IEC 60502, black or red or customization
Applications
For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.
Standards
International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS, DIN and ICEA upon request
Installation
1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
Technical Data:
Nom. Cross-section of conductor | Insulation Thickness | Sheath Thickness | Approx. O.D. | Approx. Weight | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | mm | mm | mm | kg/km | Ω /km | kV/5min | In air (A) | In soil (A) |
1×70 | 10.5 | 2.4 | 41 | 1604 | 0.443 | 91 | 265 | 270 |
1×95 | 10.5 | 2.4 | 43 | 1767 | 0.320 | 91 | 320 | 325 |
1×120 | 10.5 | 2.4 | 44 | 1923 | 0.253 | 91 | 370 | 370 |
1×150 | 10.5 | 2.5 | 46 | 2103 | 0.206 | 91 | 420 | 420 |
1×185 | 10.5 | 2.5 | 48 | 2282 | 0.164 | 91 | 480 | 480 |
1×240 | 10.5 | 2.6 | 50 | 2584 | 0.125 | 91 | 565 | 560 |
1×300 | 10.5 | 2.7 | 53 | 2891 | 0.100 | 91 | 650 | 640 |
1×400 | 10.5 | 2.8 | 56 | 3325 | 0.0778 | 91 | 780 | 760 |
1×500 | 10.5 | 2.9 | 59 | 4076 | 0.0605 | 91 | 915 | 875 |
1×630 | 10.5 | 3.0 | 63 | 4305 | 0.0469 | 91 | 1030 | 990 |
1×800 | 10.5 | 3.1 | 68 | 5054 | 0.0367 | 91 | 1180 | 1140 |
1×1000 | 10.5 | 3.3 | 72 | 5878 | 0.0291 | 91 | 1350 | 1280 |
1×1200 | 10.5 | 3.4 | 76 | 6657 | 0.0247 | 91 | 1500 | 1390 |