Product Details:
Payment & Shipping Terms:
|
Working Temperature: | 90 ℃ | Type: | Lower Voltage 0.6/1kV |
---|---|---|---|
Insulation Color: | Orange Or Optional | Function: | Fire Resistant |
Sample: | 1-1.5m | Application: | Power Station |
Corporation: | Shenghua Group | Brand: | Sh Cable |
Highlight: | low smoke halogen free cable,lszh power cable |
Orange Color Copper Conductor Fire Resistive 600/1000V Power Cable IEC60502
Fire Resistive Power Cable, Fire Rated Power Cable, Flame Retardant Power Cable
Specifications:
Conductor | : | Plain Annealed, Stranded Circular Non – Compacted or Circular Compacted or Shaped Copper |
---|---|---|
Fire Barrier | : | Mica Tape |
Insulation | : | XLPE (For FR-200) or LSOH (For FR-300) |
Sheath | : |
LSOH |
Number of cores x cross section | Insulation thickness | Sheath thickness | Overall diameter | Max. Conductor resistance | Inductance | |
DC at 20°C | AC at 70°C | |||||
No. xmm2 | mm | mm | mm | ohm/km | ohm/km | mH/Km |
N2XH (Single Core Power Cables with Mica Glass Tape) | ||||||
1 x 1.5 RE | 0.7 | 1.4 | 6.2 | 12.1 | 15.4 | 0.458 |
1 x 1.5 RM | 0.7 | 1.4 | 6.4 | 12.1 | 15.4 | 0.458 |
1 x 2.5 RE | 0.7 | 1.4 | 6.6 | 7.41 | 9.45 | 0.439 |
1 x 2.5 RM | 0.7 | 1.4 | 6.8 | 7.41 | 9.45 | 0.439 |
1 x 4 RE | 0.7 | 1.4 | 7.0 | 4.61 | 5.88 | 0.420 |
1 x 4 RM | 0.7 | 1.4 | 7.3 | 4.61 | 5.88 | 0.420 |
1 x 6 RE | 0.7 | 1.4 | 7.5 | 3.08 | 3.93 | 0.394 |
1 x 6 RM | 0.7 | 1.4 | 8.0 | 3.08 | 3.93 | 0.394 |
1 x 10 RE | 0.7 | 1.4 | 8.3 | 1.83 | 2.33 | 0.366 |
1 x 10 RM | 0.7 | 1.4 | 8.8 | 1.83 | 2.33 | 0.366 |
1 x 16 RM | 0.7 | 1.4 | 10.0 | 1.15 | 1.47 | 0.341 |
1 x 25 RM | 0.9 | 1.4 | 12.0 | 0.727 | 0.923 | 0.325 |
1 x 35 RM | 0.9 | 1.4 | 13.0 | 0.524 | 0.668 | 0.311 |
1 x 50 RM | 1.0 | 1.4 | 14.5 | 0.387 | 0.494 | 0.302 |
1 x 70 RM | 1.1 | 1.5 | 16.5 | 0.268 | 0.342 | 0.291 |
1 x 95 RM | 1.1 | 1.5 | 18.5 | 0.193 | 0.247 | 0.284 |
1 x 120 RM |
1.2 | 1.6 | 20.5 | 0.153 | 0.196 | 0.279 |
Note:
1. The models also contain fire-resistant type of low voltage power cable.
2. When signing the contract, the fire resistant type must be specified. For example, if type A is preferred, please add "A" to the end of "ZR", forming "ZRA", and A is usually used in places where the fire resistant property is highly required. B and C follow the same rule. In addition, if there is no letter after "ZR", the cable will be produced following "ZRC".
Quality Assurance:
With Yiteng, all cables are produced by strict inspection and testing:
1). Raw Material: Copper, Aluminium, PVC, PE and XLPE granules and all other materials for producing cables are all inspected carefully automatically. Only the qualified will be applied into cable production, the disqualified will be rejected.
2). Production Procedure: Cables are produced by advanced cable production machines.
3). Testing: Cables will not be packed until they are tested totally qualified. Cable Testing Machines includes Online Core Shift Detection Device, Tension Tester, Aging Test Chamber, Experimental Apparatus of Combustion, Insulation Resistance Tester and etc…